How it adds up
Every appliance pulls current, and current is what heats a power board and trips a breaker. Plug Budget turns each thing’s watts into amps (watts divided by volts, 230 in Australia), then adds up only the things you’ve ticked as on at the same time. A power board plugged into a wall socket sends all of its load through that socket, so the socket carries the board’s total too, and everything on one breaker shares that breaker’s amps. Under 80% of a rating is green. Over 80% is amber, the zone where boards get warm when it lasts for hours. Over 100% is red.
Two things that heat or draw big (a kettle, a heater, a toaster, an air fryer, anything 1,500 W or more) shouldn’t share one board, and a board plugged into another board is a daisy chain that piles everything onto the first plug. The suggestions try one move at a time, always the move that helps most, and only to a spot where nothing ends up over its rating. When no move can fix it, the honest answer is to take turns.
A word on safety. This is an estimate from typical numbers, so the label on your actual appliance wins: it’s usually on the bottom or near the cord. Boards in Australia are often marked 10 A or 2,400 W, worked out at 240 V; at 230 V the same 10 A is about 2,300 W, so I count amps. If a plug or board feels hot, smells, or a breaker keeps tripping, unplug things and talk to an electrician.